Fiber Optic Cable Installation and Handling Instructions

 

Introduction


Fiber optic cables can be easily damaged if they are improperly handled or installed. It is imperative that certain procedures be followed in the handling of these cables to avoid damage and/or limiting their usefulness. The information contained in this article should serve as a guide to proper handling and installing fiber optic cables.

Overview

Do not exceed maximum cable lengths
Do not exceed minimum bend radius for a given cable type


Avoid twisting cable Optical fibers require special care during installation to ensure reliable operation. Installation guidelines regarding minimum bend radius, tensile loads, twisting, squeezing, or pinching of cable must be followed. Cable connectors should be protected from contamination and scratching at all times. Violation of any of these parameters causes increased attenuation or permanent damage to the cable. The following are a few general comments to consider when installing fiber optic cables. Make sure you check the installation instructions of the module for the appropriate cable lengths to ensure proper operation. You may experience additional attenuation loss when using bulkhead connectors to join cables even when the total length is less than the maximum. Care should be used in maintaining total attenuation budget when joining cables with bulkhead connectors. Exceeding the bend radius of the cable can cause unseen damage to the fibers of the cables that may not manifest itself for a period of time. This can lead to an expensive restringing of cables at a later date.
Use proper pulling techniques in laying out your cable. Putting twists in the cable greatly increases your chances of breaking the fibers.


Fiber Optic Cable Pulling Techniques
On runs from 40m to 100m, use proper lubricants and make sure they are compatible with the cable jacket.
On runs over 100m, use proper lubricants and pull from the middle out to both ends. Installation methods for both wire cables and optical fiber cables are similar. Just remember these rules:

Routing Fiber Optic Cables
Take care to properly route cables through cabinets and right angle raceways.

Cleaning Techniques for Fiber Optic Cables

Cleaning Fiber Optic Transceivers
Proper cleaning of the fiber optic cable ends and transceivers is essential to minimize system attenuation. Dirty fiber optic cables cross contaminate their mating transceivers. Conversely a dirty transceiver contaminates its mating fiber optic cable. There are a variety of ways to clean fiber optic components. Readily available prepackaged wipes, swabs and, canned air are suitable. Always choose an optical grade cleaner for these purposes. Use a wet wipe to loosen particles on the end of the cable connector using a circular or straight wiping motion while using care to avoid wiping over area of pad that has already been used. Do not use a back and forth scrubbing action. Always use a clean area of the swab for each connector. When in doubt use a fresh wipe. Follow up the wet wipe cleaning with a dry wipe to remove any residue. Use canned air to remove any lint from the cable end.
Choose an optical grade lint free swab that fits easily into the transceiver barrel. Under some conditions a fast evaporating optical cleaning solvent may be used to saturate the swab (e.g., 99% pure alcohol). The swab should be gently placed into the barrel of the connector and rotate no more than one turn. DO NOT rotate back-and-forth or round-and-round because this could grind debris into the transceiver. The swabs should only be used ONCE. Use a dry clean swab and insert into barrel and rotate once. Discard swab. Use canned air to blow out the barrel.

Fiber-Optic Specifications
What are the specifications of the fiber-optic cables Time-O-Matic ships with an LED sign?
Watchfire Signs has used dual fiber-optic cables since June of 2005. Specifications on the dual fiber are as follows:

  1. Plenum rated. Approved to be placed in plenum spaces of buildings. OFNP listed.
  2. Standard ST connectors
  3. Diameter - 62.5 microns
  4. Multi-mode (Multi-mode fiber is required even when a customer supplies his own fiber. Single-mode fiber has a smaller core than multi-mode, typically 12.5 microns vs. 62.5 microns)
  5. Wavelength, for serial communications (Fiber Com box, CB) 820nm, For Ethernet over Fiber 1310nm
  6. Minimum Bend Radii: 2.0" operation, 3.0" bend radius installation
  7. Pull Strength - 303 lbs. during installation; 90 lbs. during operation
  8. Entire Cable Diameter - 0.19"
  9. Glass core

NOTE: Multi-mode fiber is typically used to send data over short distances (up to 600 m or 0.37 miles), as the wavelength of the source LED is 850 nm (nanometers). Single-mode fiber is typically used to send data over long distances, as the wavelength of the source LED is 1310 or 1550 nm.
NOTE: Watchfire Signs used to ship single fiber-optic cable. Those specifications were identical to the new specifications, except for pulling strength; pulling strength was rated at 100 pounds. The smaller size of a single cable allowed the fiber to be placed in smaller diameter conduit.